This browser cannot use the USB adapter. Please open this page in Google Chrome on the Mac (Safari and Firefox do not support USB serial). You can still try the Demo controller.
1 · Wiring
Check this before pressing Connect.
Mac (Chrome)→USB hub→USB TO RS485→DomBusTracker2
Adapter
Controller
A+
A
B−
B
GND
GND
✓Controller powered (24 V). Its LEDs flash the address at power-on.
✓Adapter red PWR light is ON.
!No reply? Swap A and B wires and try again.
2 · Connect
Chrome will ask which USB port to use. Pick “USB Single Serial” or “FT232R”.
Searching…
Controller found
—
Address
—
reg 8192
Speed / parity
—
reg 8193 / 8194
Firmware
—
reg 8198–8199
Link
—
replies / errors
Live status
Read every 1 second (registers 0–27)
—
Turn (reg 23)
—%
—
Tilt (reg 22)
—%
—
Motors (reg 0–3)
—
—
Limit switches (reg 18–19)
—
East = 0% · West = 100%
Sun sensor N / S / E / W
—
% of full light (reg 6–9)
Balance N-S / E-W
—
reg 20 / 21
Tracker state
—
reg 26
Errors
—
reg 27
Settings · Registers
Every write asks you to confirm first. Factory reset is always blocked.
Change log
Every write is recorded on this Mac. (Saving to the server comes next.)